WatchNet RTS series Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 10
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
5
Output Control Messages
The table below describes the typical commands used to turn on and off output devices (Relays, X-10)
connected to the control panel and the status query and subsequent report message from the panel.
Control Panel Output On/Off Commands and Status Reports
Action String Definition
Output ON
0AcnDD00CC (CR-LF)
Example: turn on Control Panel Output 1: 0Acn0105 (CR-
LF)
Output OFF
0ACFDD00CC (CR-LF)
Example: turn off Control Panel Output 1: 0Acf0105 (CR-
LF)
Output Status
Request
08cs0062 (CR-LF) The VISTA panel will respond to this request with a Control
Panel Output Status Report for all 96 outputs
Output Status
Report
68CSD00CC (CR-LF) The VISTA panel sends this message in response to an
Output Status Request. The data portion of this message is
96 characters long, one character for each control channel in
order. The value will be U (U
NPROGRAMMED
), 0 (O
FF
), or 1
(O
N
).
Example: With control channel 1 O
FF
, channel 2 O
N
,
channel 3 U
NPROGRAMMED
, and channel 4 O
FF
, the message
would begin 40CS01U0.
System Event Notification Messages
The control panel can be programmed (field
05) to send system event notification messages when certain
events occur. The 12-character data field of this message is divided into six 2-character sub fields. A typical
packet format is as follows: 14NQDDDDDDDDDDDD00CC (CR-LF). The table below describes the
different components of a System Event Notification Message Packet format. Example: Zone 14 Open at
10:23 AM on February21 is sent as: 14NQ2B14231021020038 (CR-LF)
NOTES: Messages contain printable ASCII characters with the exception of the Terminator.
All hex values are entered in upper case only.
The messages are reported in real time.
System Event Notification Packet Format
Component Symbol Format
Event Type TT
0X00 0X30 (Data in the TT position will
be one of the report types that appears in
the System Event Types table below)
Zone or User
Number
ZZ
00 95 (0 referenced: Zone or User 1 is
00)
Minutes MM
00 59
Hours HH
00 23
Day DD
01 - 31
Month XX
01 - 12
Vista de pagina 4
1 2 3 4 5 6 7 8 9 10

Comentarios a estos manuales

Sin comentarios